{"id":707,"date":"2023-04-18T15:19:48","date_gmt":"2023-04-18T20:19:48","guid":{"rendered":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/?page_id=707"},"modified":"2025-07-28T15:52:46","modified_gmt":"2025-07-28T20:52:46","slug":"beckman-coulter-cytoflex-s","status":"publish","type":"page","link":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/equipment-applications\/beckman-coulter-cytoflex-s\/","title":{"rendered":"Beckman Coulter CytoFLEX S"},"content":{"rendered":"\n<table id=\"tablepress-8\" class=\"tablepress tablepress-id-8\" summary=\"\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">CytoFlex S<\/th><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Laser<\/td><td class=\"column-2\">Fluorescent Channel<\/td><td class=\"column-3\">CytoFlex S Channel<\/td><td class=\"column-4\">Commonly Used Fluorescent Dyes<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">405 nm <\/td><td class=\"column-2\">450\/45 BP<\/td><td class=\"column-3\">PB450<\/td><td class=\"column-4\">BV421, SuperBright 436, StarBright Violet 440, CF405S, V450, eFluor 450, Pacific Blue, Alexa Fluor 405, Spark Violet 423, Zombie Violet, DAPI<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">525\/40 BP<\/td><td class=\"column-3\">KO525<\/td><td class=\"column-4\">StarBright Violet 515, StarBright Violet 475, BV 480, BV 510, Pacific Green, Pacific Orange, Zombie Aqua,<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">610\/20 BP<\/td><td class=\"column-3\">Violet 610<\/td><td class=\"column-4\">BV605, Qdot 605<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">660\/20 BP<\/td><td class=\"column-3\">Violet 660<\/td><td class=\"column-4\">StarbBright 670, BV 650, SuperBright 645, Qdot 655<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">488 nm<\/td><td class=\"column-2\">525\/40 BP<\/td><td class=\"column-3\">FITC<\/td><td class=\"column-4\">FITC, Alexa Fluor 488, Brilliant Blue 515, Spark Blue 574, Vio515, Zombie Green<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">690\/50 BP<\/td><td class=\"column-3\">PerCP<\/td><td class=\"column-4\">StarBright Blue 700, Brilliant Blue 700, PerCP-eFluor 700, PerCP-Vio700, PE-Fire 700, PerCP-Cy5.5, PE-Cy5.5, PerCP<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">561 nm <\/td><td class=\"column-2\">585\/42 BP<\/td><td class=\"column-3\">PE<\/td><td class=\"column-4\">PE, CF555, Alexa Fluor 555, Spark YG 581<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">610\/20 BP<\/td><td class=\"column-3\">ECD<\/td><td class=\"column-4\">PE-CF594, PE-Dazzle 594, PE-Texas Red, ECD, PE-eFluor 610, Propidium Iodide, Zombie Red<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">690\/30 BP<\/td><td class=\"column-3\">PC5<\/td><td class=\"column-4\">PE-Cy5, PE-Alexa 647, 7-AAD<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">780\/60 BP<\/td><td class=\"column-3\">PC7<\/td><td class=\"column-4\">PE-Cy7, PE-Vio770, PE-Fire 840<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">633 nm<\/td><td class=\"column-2\">660\/20 BP<\/td><td class=\"column-3\">APC<\/td><td class=\"column-4\">APC, Alexa Fluor 647, eFluor 660, APC-Cy5.5, Sytox Red, Ghost Dye Red 710, Live\/Dead Fix Far Red<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">712\/25 BP<\/td><td class=\"column-3\">APC-A 700<\/td><td class=\"column-4\">APC-Alexa Fluor 700<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">780\/60 BP<\/td><td class=\"column-3\">APC-A 750<\/td><td class=\"column-4\">APC-Alexa 750, APC-eFluor 780, APC-Vio770, APC-Fire 750, APC-Fire 810, APC-Cy7, Live\/Dead Fix Near IR, Zombie NIR, Ghost Dye Red 780<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-8 from cache -->\n","protected":false},"excerpt":{"rendered":"CytoFlex S LaserFluorescent ChannelCytoFlex S ChannelCommonly Used Fluorescent Dyes 405 nm 450\/45 BPPB450BV421, SuperBright 436, StarBright Violet 440, CF405S, V450, eFluor 450, Pacific Blue, Alexa Fluor 405, Spark Violet 423, Zombie Violet, DAPI 525\/40 BPKO525StarBright Violet 515, StarBright Violet 475, BV 480, BV 510, Pacific Green, Pacific Orange, Zombie Aqua, 610\/20 BPViolet 610BV605, Qdot 605 [...]","protected":false},"author":354,"featured_media":0,"parent":362,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-707","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Beckman Coulter CytoFLEX S - Flow Cytometry<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/wp.uthscsa.edu\/flow-cytometry\/equipment-applications\/beckman-coulter-cytoflex-s\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Beckman Coulter CytoFLEX S - Flow Cytometry\" \/>\n<meta property=\"og:url\" content=\"https:\/\/wp.uthscsa.edu\/flow-cytometry\/equipment-applications\/beckman-coulter-cytoflex-s\/\" \/>\n<meta property=\"og:site_name\" content=\"Flow Cytometry\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-28T20:52:46+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/wp.uthscsa.edu\\\/flow-cytometry\\\/equipment-applications\\\/beckman-coulter-cytoflex-s\\\/\",\"url\":\"https:\\\/\\\/wp.uthscsa.edu\\\/flow-cytometry\\\/equipment-applications\\\/beckman-coulter-cytoflex-s\\\/\",\"name\":\"Beckman Coulter CytoFLEX S - Flow Cytometry\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/wp.uthscsa.edu\\\/flow-cytometry\\\/#website\"},\"datePublished\":\"2023-04-18T20:19:48+00:00\",\"dateModified\":\"2025-07-28T20:52:46+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/wp.uthscsa.edu\\\/flow-cytometry\\\/equipment-applications\\\/beckman-coulter-cytoflex-s\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/wp.uthscsa.edu\\\/flow-cytometry\\\/equipment-applications\\\/beckman-coulter-cytoflex-s\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/wp.uthscsa.edu\\\/flow-cytometry\\\/equipment-applications\\\/beckman-coulter-cytoflex-s\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/wp.uthscsa.edu\\\/flow-cytometry\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instruments\",\"item\":\"https:\\\/\\\/wp.uthscsa.edu\\\/flow-cytometry\\\/equipment-applications\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Beckman Coulter CytoFLEX S\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/wp.uthscsa.edu\\\/flow-cytometry\\\/#website\",\"url\":\"https:\\\/\\\/wp.uthscsa.edu\\\/flow-cytometry\\\/\",\"name\":\"Flow Cytometry\",\"description\":\"Flow Cytometry\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/wp.uthscsa.edu\\\/flow-cytometry\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Beckman Coulter CytoFLEX S - Flow Cytometry","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/equipment-applications\/beckman-coulter-cytoflex-s\/","og_locale":"en_US","og_type":"article","og_title":"Beckman Coulter CytoFLEX S - Flow Cytometry","og_url":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/equipment-applications\/beckman-coulter-cytoflex-s\/","og_site_name":"Flow Cytometry","article_modified_time":"2025-07-28T20:52:46+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/equipment-applications\/beckman-coulter-cytoflex-s\/","url":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/equipment-applications\/beckman-coulter-cytoflex-s\/","name":"Beckman Coulter CytoFLEX S - Flow Cytometry","isPartOf":{"@id":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/#website"},"datePublished":"2023-04-18T20:19:48+00:00","dateModified":"2025-07-28T20:52:46+00:00","breadcrumb":{"@id":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/equipment-applications\/beckman-coulter-cytoflex-s\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/wp.uthscsa.edu\/flow-cytometry\/equipment-applications\/beckman-coulter-cytoflex-s\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/equipment-applications\/beckman-coulter-cytoflex-s\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/"},{"@type":"ListItem","position":2,"name":"Instruments","item":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/equipment-applications\/"},{"@type":"ListItem","position":3,"name":"Beckman Coulter CytoFLEX S"}]},{"@type":"WebSite","@id":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/#website","url":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/","name":"Flow Cytometry","description":"Flow Cytometry","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/wp-json\/wp\/v2\/pages\/707","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/wp-json\/wp\/v2\/users\/354"}],"replies":[{"embeddable":true,"href":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/wp-json\/wp\/v2\/comments?post=707"}],"version-history":[{"count":0,"href":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/wp-json\/wp\/v2\/pages\/707\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/wp-json\/wp\/v2\/pages\/362"}],"wp:attachment":[{"href":"https:\/\/wp.uthscsa.edu\/flow-cytometry\/wp-json\/wp\/v2\/media?parent=707"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}